Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter

Product Details
Customization: Available
After-sales Service: in Time Respond with 2 Hours
Warranty: 12 Months
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
  • Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
  • Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
  • Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
  • Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
  • Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Information
  • FAQ
Overview

Basic Info.

Model NO.
CXMCLDT
Accuracy
>±1%
Main Application
Water, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN15~DN600
Sensor
Tube/Flange
Application
Energy Metering
Type
Differential Pressure Flow Meter
Measuring Media
Liquid/Gas
Measuring Principle
Bernoulli Equation
Measurement Object
Closed Pipeline
Certification
ISO
Installation
Easy
Material
SS304
Power Supply
220VAC/ 24VDC/Battery
Customized Support
OEM, ODM, Obm
Ambient Temperature
-40 - 55 °c
Process Temperature
-20 ~ 300 Centidegree
Measuring Medium
Liquid Water
Diameter
DN 25-DN3000
Display
LCD Display
Transport Package
Plywood Case
Specification
Stainless Steel
Trademark
KCMC
Origin
Henan, China
HS Code
9026100000
Production Capacity
2000 Pieces / Year

Product Description

Product Description
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow MeterThe orifice plate flow meter is a type of differential pressure flow meter that is commonly used in clean liquid, gas, and stream mass flow measurement. It is available for all pipe sizes, and if the pressure loss it requires is free, it is very cost-effective for measuring fluid flows in larger pipes (over 6" diameter). The orifice plate is also approved by many standards organizations for the custody transfer of liquids and gases.

The orifice flow equations - which make use of the Bernoulli Equation - that are used today still differ from one another, although the various standards organizations are working to adopt a single, universally accepted orifice flow equation. Orifice sizing programs usually allow the user to select the flow equation desired from among several.
The orifice plate can be made of any material, although stainless steel is the most common. The thickness of the plate used (1/8 - 1/2") is a function of the line size, the process temperature, the pressure, and the differential pressure. The traditional orifice is a thin circular plate (with a tab for handling and for data), inserted into the pipeline between the two flanges of an orifice union. This method of installation is cost-effective, but it calls for a process shutdown whenever the plate is removed for maintenance or inspection. In contrast, an orifice fitting allows the orifice to be removed from the process without depressurizing the line and shutting down flow. In such fittings, the universal orifice plate, a circular plate with no tab, is used.
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
Product Parameters

Features of Annular Orifice Plate:
Measuring mediu

1. flow of general fluids;

2. fluids containing various impurities (such as dust, suspension, precipitation, etc.)

3. various coal gas hot wind, flue gas, natural gas, cooling water and so on.


Although it is a simple device, the orifice plate is, in principle, a precision instrument. Under ideal conditions, the inaccuracy of an orifice plate can be in the range of 0.75-1.5% AR. Orifice plates are, however, quite sensitive to a variety of error-inducing conditions. Precision in the bore calculations, the quality of the installation, and the condition of the plate itself determine total performance. Installation factors include tap location and condition, condition of the process pipe, adequacy of straight pipe runs, gasket interference, misalignment of pipe and orifice bores, and lead line design. Other adverse conditions include the dulling of the sharp edge or nicks caused by corrosion or erosion, warpage of the plate due to waterhammer and dirt, and grease or secondary phase deposits on either orifice surface. Any of the above conditions can change the orifice discharge coefficient by as much as 10%. In combination, these problems can be even more worrisome and the net effect unpredictable. Therefore, under average operating conditions, a typical orifice installation can be expected to have an overall inaccuracy in the range of 2 to 5% AR.

The typical custody-transfer grade orifice meter is more accurate because it can be calibrated in a testing laboratory and is provided with honed pipe sections, flow straighteners, senior orifice fittings, and temperature-controlled enclosures.
  • When to measure saturated steam superheated steam, the accumulation of condensate formed by stopping steam can be avoided , and when supplying steam again, it can quickly enter the accurate measurement.
  • There is a straight measuring tube in the instrument body, when installed on-site, there is hardly no affected to the instrument measurement by the installation errors (such as off-center, sealing gasket into the pipeline).
  • Using the "pressure balancing ring" structure, when the length of the straight pipe section is not long enough, it can still be accurately measured. For example: in the downstream of a 90°elbow, it will be available where is a 2D length before the flowmeter; in the downstream of a 30° elbow, there is a 0.5D length before the flowmeter is available either.
  • Adopting the "welding method" connection, suitable for high temperature and high pressure fluids (such as superheated steam), low cost, reliable work, stable performance.
  • The use of "jacket insulation" structure, suitable for easily crystallized, easily vaporized and other need to be warmed or cooled fluids (such as liquid ammonia, some chemical products, etc.).
Packaging & Shipping
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter

 

Company Information
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
Kaifeng ChuangXin Measurement and Control Instrument Co., Ltd.was established in 2009, and is a professional company occupied in  instruments R & D, manufacturer, sales and technical counsel.The main products are Electromagnetic Flowmeter, Vortex Flowmeter, Turbine Flowmeter, Orifice Flowmeter, Metal float flowmeter, Ultrasonic flowmeter, Swirlmeter and some other process control instruments. Our products are widely used in water treatment, environmental protection, water conservancy, petroleum, chemical, pharmaceutical, natural gas, electricity, heating supplying, papermaking, metallurgy, scientific research, national defense project and other fields.
 
Our enterprise development strategy is "People-Oriented, Quality First, Development on Technology ". We attach importance to management internally, and expanding the market externally, to focus on the business philosophy of quality products, good service, reasonable price, honest and trustworthy all along.
Our Name Chuangxin in Chinese means to innovate. Someone says Innovation is the core of the manufacturing industry, it is to master the key core technologies, which must be achieved by self-reliance and independent innovation, we strive all the time in this direction.
Keeping continuous innovating and improving to provide satisfactory products and services to our global clients.
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow MeterOrifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow MeterOrifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter
FAQ

Orifice Plate Flowmeter Annular Gas Orifice Plate DN50 Differential Flow Meter

Q: What about the quality assurance service?
A: Our guarantee period is 12 months, the product quality problem that appears in the quality assurance period, we give free maintenance or change.

Q: Are you trading company or manufacturer ?
A: We are factory and has manufacture kinds of flowmeter for more than 14years.

Q: How about your delivery time?
A: Depends on the order quantity, generally it is 2-4 working days if the goods are in stock.
or it is 7-9 working  days if the order quantity is with 50 sets to be produced for all processes.


Q: Could we visit your factory?
A: Certainly, we welcome all clients visit us at their convenience for further understanding each other.

Q: What is your terms of payment ?
A: Payment below US$1000,  100% in advance; Payment over US$1000 can be 30%  deposit before production, and the balance settled before shippment.

 

Q: How would you deliver the shipment ?
A: Acocrding to the order quantity or customers' request, express, air, sea are avalible.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier