Customization: | Available |
---|---|
After-sales Service: | in Time Respond with 12 Hours |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
Liquid, gas, steam (single-phase medium or can be considered as a single-phase medium)
|
When the dryness of saturated steam is ≥85%, it can be considered as a single-phase medium
|
|
Medium Temperature
|
40ºC~+200ºC; -40ºC~+280ºC; 40ºC~+350ºC
|
Medium Pressure
|
1.6Mpa; 2.5Mpa; 4.0Mpa (Other pressure can be customized)
|
Accuracy
|
1.0%(flange); 1.5% (insertion)
|
Measuring range Ratio
|
1:10(Standard air condition as reference); 1:15(Liquid)
|
Velocity Range
|
Liquid: (0.4~7)m/s; Gas: (4.0~60)m/s; Steam: (5.0~70)m/s
|
Pipe Diameter Range and connection
|
DN15-DN300(Flange), DN80-DN2000(Insertion), DN15-DN100(Thread), DN15-DN300(Wafer), DN15-DN100(Sanitary)
|
Material
|
SS304(Standard), SS316(Optional)
|
Pressure Loss Coefficient
|
Cd≤ 2.6
|
Vibration Acceleration Allowed
|
≤0.2g
|
Power Supply
|
DC24V or 3.6V battery power
|
Protection Class
|
IP65
|
IEP /ATEX
|
II 1G / Ex ia IIC T5 Ga
|
Environmental Conditions
|
Ambient temperature: -40ºC~55ºC
|
Relative humidity: ≤85%
|
|
Atmospheric pressure:(86~106) KPa
|
|
Output Signal
|
Pulse frequency signal2-3000Hz, Low level≤1V, high level≥6V
|
Two-wire system 4-20mA signal(isolated output), Load≤500
|